VDO Ammeter Gauge 60Amp
Suitable for most engines. Charge and battery condition. Voltage independent – suitable for 12 & 24V Ammeters with internal shunt are easily identified by the heavy duty threaded terminals. Heavy duty wire must be used for wiring. Illumination globe holder included.
For 24V application use globe 999-065-002 For 12V application use globe 999-065-001
VDO Ammeter Gauges 60Amp
Colour: Black
Panel hole diameter: 52 mm - 2 1/16"
Range: -60A to +60A DC
Operating voltage: None
1 Piece OEM Ampèremeter
Sizes and mounting:
Installation (Hole) diameter and Outside diameter: |
52 mm - 2 1/16 Inch en 59.25 mm - 2 1/3 Inch |
Installation depth: |
67.5 mm |
Locking height with Spinlock nut: |
Not available |
Locking height with bracket: |
0.5 mm - 8 mm |
Flushmount: |
None |
Functionality:
Ampere measurement range: |
-60A to +60A DC |
Shunt: |
Not applicable |
Signal input ammeter gauge: |
-60A to +60A DC |
Accuracy: |
Not specified by VDO |
Connection: |
M5 hexnut |
Illumination connection: |
AMP Male blade connector 6,3 x 0,8mm (2x) |
Power supply:
Operating voltage (Illumination only): |
12 Volt standard - 24 Volt optional |
Current consumption (Illumination only): |
12 Volt 2 Watt - 24 Volt 2 Watt |
Reverse polarity protection: |
Not applicable |
Short circuit protection: |
Not applicable |
Dial & Pointer:
Deflection angle: |
320° |
Dial colour: |
Black |
Dial Illumination: |
Floodlight 12V - 2 Watt White - Green - Red and 24V - 2 Watt - Optional |
Pointer: |
Red backlight |
Warning indication: |
None |
Programming: |
None |
Design:
Model: |
Cockpit International |
Lens: |
Single - Anti-glare |
Standard bezel: |
Triangular black (Threaded ring) |
Protection and standards:
Front protection class: |
IP64 (DIN 40050) - Ozon proof - UV proof |
Rear protection class: |
IP42 (DIN 40050) |
Relative humidity: |
Not specified by VDO |
Operating temperature: |
-30°C to +85°C |
CE standard: |
Yes |
DNV GL Certification: |
Not specified by VDO |
Mechanical shock 8 hours: |
Max: 1G - 25Hz - 2000Hz |
EMC test: |
According to EN 13309 and ISO 13766 |
Nominal position: |
NL 0 to NL 90 - DIN 16257 |
Housing: |
Plastic flame retardant |