Industrial Pressure Gauges
PRESSURE TRANSMITTER
General purpose pressure transmitters
are intended for the general industry such as hydraulic, pneumatic,
mining, chemical, petro-chemical, shipping, machine buliding etc.
- All s/steel construction and wetted parts.
Din plug for wiring
- 4-20 mA output, 10-30 V DC
- 1/2" BSP male connection or with flush
diaphragm
- -100...0...250MPa, bar, psi etc.
- Universal DIN type, 4 digit LED plug-on display
optional
- Accuracy 0.5% and 0.25% F.S.
Service Intended
Suitable for the majority of general industrial control
applications such as hydraulics, pneumatics,
pharmaceutical and food & beverage.
Construction
Material: Stainless steel 316
Wetted Parts; Stainless steel 316
Flush diaphragm for type PT2: Stainless steel 316
Pressure Connections
Material: Stainless steel 316
Size: 1/2” BSP
Ingress Protection
IP 65
Working Pressure
Steady: Full scale value
Over Range Limit: 150% of FS
Burst Pressure: 3 x FS
Signal Output
4 - 20 mA 2-wire
Power Supply
10 - 30 V DC
Accuracy Class
0.5% (0.25% optional)
Compensated Temperature Range
0 to 85 °C
Temperature Error: Zero and span < 0.02% FS / K
Installation
Careful consideration, regarding process conditions,
should be taken when installing transmitters. Damage
to the transmitter may be caused by excessive
vibration, pulsation, temperature or over pressure.
A capillary assembly fitted to the transmitter to remove
the transmitter from the above conditions may increase
instrument life.
Fluid hammer, surges or pressure spikes must be
avoided by fitting a suitable snubbing device.
. Typical symptoms of damage:
• The transmitter will indicate an output at zero
pressure
• The transmitter output remains constant while
pressure is applied or no output is indicated at all.
Zero and Span Adjustment
Zero and span adjustment is not normally required but
may be done on site to trim offsets in the process
system.
Although field calibratable we recommend that the
instrument be returned to the factory for the necessary
adjustments as proper re-calibration requires a
calibration standard at least 3 x more accurate than the
accuracy of the transmitter.
Individual span or zero adjustment may also have an
effect on each other.
Optional Extras
Calibration certificate
Diaphragms seals fitted